(317) 555-0142

Can a tree is on the power line / there are sparks outside be fixed without removing the tree?

The question is premature and stays premature until the line is de-energized and grounded by the utility crew. After that, plenty of these trees are perfectly sound and need nothing more than directional clearance pruning to get the canopy back out of the corridor and keep it out.

How long you have to decide

Now — call 911 and the utility. Keep people and pets at least 10 feet back, which is OSHA's clearance requirement for unqualified persons around lines up to 50kV, and keep everyone off any wet path to the tree. If a conductor is down near you, shuffle away with your feet together rather than stepping. Critically: distribution circuits use automatic reclosers, so a line that went dead can re-energize by itself within seconds without any crew arriving. Never treat quiet as safe.

Related

Get it done

Talk to someone(317) 555-0142